Troubleshooting¶
The ifm moneo signals are not processed¶
Symptom: Messages of ifm moneo devices arrive in IoT Link but the connector does not handle them.
Cause: The setup of the device, the routing rule or the tag settings does not match.
Solution:
- In IoT Device, set Controller Adapter to ifm moneo. On the CIM device in PrintVis, choose the device type ifm moneo IoT and set Device Adapter to ifm moneo.
- In IoT Link, check that a routing rule with the source system
moneoexists and that you chose Activate Configuration. - Open IoT ifm Tag Settings and check that the tags match the field names in your messages. Change a tag only if your ifm moneo messages use other field names.
The controller is marked offline¶
Symptom: A controller of an ifm moneo device is marked as offline.
Cause: The adapter received no signals within the Maximum Allowed Idle Time (seconds).
Solution:
- Check that the device still sends data to IoT Link.
- If signals normally arrive less often, increase Maximum Allowed Idle Time (seconds) in the adapter setup.
The adapter is not shown as a choice¶
Symptom: ifm moneo is not available as Controller Adapter or Device Adapter.
Cause: The app is not installed or not up to date, or IoT Link or the connector is missing.
Solution:
- Open Extension Management and check that the adapter, the IoT-2-PrintVis Connector and IoT Link are installed.
- Check the requirements.
Still stuck?¶
Open an issue in the support repository and include the app name, the app version, your Business Central version and a short description of the problem. Do not post passwords, keys, tokens, tenant IDs or environment URLs.