Troubleshooting¶
The electronic job ticket shows COUNTER OFFLINE, IOT-HUB CONNECTION LOST or INVALID LICENSE¶
Symptom: The Counter part on the electronic job ticket shows one of these warnings.
Cause: The warning names the problem: the counter is offline, the connection to the IoT Hub is lost, or the license is not valid.
Solution:
- For IOT-HUB CONNECTION LOST, check the connection in the IoT Setup of IoT Link, see its Troubleshooting.
- For COUNTER OFFLINE, open IoT Device Status and check whether the input channel of the device is online and when it was last updated.
- For INVALID LICENSE, check the license plan of the apps. The license is counted per physical IoT device.
The job cannot be completed¶
Symptom: Business Central shows: "There are 1 or more shop floor entries that have unaccounted idle time. Please handle these Idle Time entries first before completing the job."
Cause: There are idle time registrations without the mandatory comments, and with Use Enhanced Idle Time Registration also without an idle type and reason code.
Solution:
- Choose Complete entries now in the notification, or open Idle Time Registrations from the electronic job ticket.
- Use Toggle No Comments Only to show the registrations that still need a comment.
- Enter the comments. With enhanced idle time registration also select the Idle Type and Reason Code.
The job does not switch to production automatically¶
Symptom: The job stays in setup although the machine runs.
Cause: The automatic switch only happens when Auto Switch to Production Mode is on for the cost center, the speed stays above the Production Speed Threshold for the Speed Duraction Threshold (sec), and the active process is a setup process.
Solution:
- Check these settings on the cost center.
- Check the current speed on IoT Device Status.
A signal is not processed¶
Symptom: A signal appears in the IoT Hub Events but has no effect.
Cause: The event was not processed successfully.
Solution:
- Open IoT Hub Events, select the event and choose Reprocess Event.
- Use Decode Properties to check the properties of the event.
Idle time stays on a device that no longer exists¶
Symptom: IoT Device Status shows a line for a device or channel that you renumbered or removed.
Cause: Business Central removes the device status lines of CIM devices that no longer exist at regular intervals.
Solution:
- Use Delete on the line, or use Clear Idle Time to reset the idle time of a device that still exists.
Still stuck?¶
Open an issue in the support repository and include the app name, the app version, your Business Central version and a short description of the problem. Do not post passwords, keys, tokens, tenant IDs or environment URLs.