The Moxa signals are not processed

Symptom: Messages of Moxa devices arrive in IoT Link but the connector does not handle them.

Cause: The setup of the device, the routing rule or the tag settings does not match.

Solution:

  1. In IoT Device, set Controller Adapter to Moxa. On the CIM device in PrintVis, choose the device type Moxa IoT and set Device Adapter to Moxa.
  2. In IoT Link, check that a routing rule with the source system moxa exists and that you chose Activate Configuration.
  3. Open IoT Moxa Tag Settings and check that the tags match the field names in your messages. Change a tag only if your Moxa messages use other names.

The adapter is not shown as a choice

Symptom: Moxa is not available as Controller Adapter or Device Adapter.

Cause: The app is not installed or not up to date, or IoT Link or the connector is missing.

Solution:

  1. Open Extension Management and check that the adapter, the IoT-2-PrintVis Connector and IoT Link are installed.
  2. Check the requirements.

Still stuck?

Open an issue in the support repository and include the app name, the app version, your Business Central version and a short description of the problem. Do not post passwords, keys, tokens, tenant IDs or environment URLs.